Glass Tubular Level Gauge for Water Level indicator
Basic Info
Model NO.: LWGY
Type: Floating Ball
Contact: Contact
Production Process: Normal Wirewound
IP Rating: IP65
Certification: ISO
Customized: Customized
.
Kind: Quartz-Tube Color
Structure: All in One
Range: 0-3m
Principle: Glass Tube
Transportation: Shipping, Air Freight
Warranty Period: 1year
Export Markets: Global
Additional Info.
Trademark: U-ideal
Packing: Wooden Case or Carton
Standard: SGS
.
Origin: Tianjin, China
HS Code: 90261000
Production Capacity: 5000
Product Description
Structure and working principle
Flanges are added to meter with up and low valves. The flanges connect with tank and make a communicator with tank. Then the liquid level will be read from the Transparent glass tube or glass plate directly.
The upper and lower valves have steel ball inside. So if the glass plate or glass tube was broken by accident, the steel ball will block the channel under pressure, and to assure the container be sealed automatically which can prevent the liquid flowing out.
There is screw fixed on the valve ends. When sampling or repairing the meter, rotate the screw and dismounting the meter.
Two
Flange diameter: DN20~DN500
Flange type:
A———FF (Face Flange)
B——–RF (Raisedface Flange)
Structure: “standard type” D——–“thermal type” W
Material: 1) Carbon Steel 2) Stainless Steel 3) PVC
Name | tubular level transmitter | ||||
output | 2-wire 2~20mA, switching alarm, LCD, Hart optional | ||||
Load | 0~500 | ||||
Level range | H=0.1~30m(special assemble if longer than 6m) | ||||
Accuracy | A:+/-5mm, B: +/-10mm, C: +/-20mm | ||||
Fluid temperature | -20~150ºC | ||||
Electric Power | DC 24V | ||||
Model selection | |||||
UQK-B | floater level transmitter | ||||
Accuracy | A | 5mm | |||
B | 10mm | ||||
C | 20mm | ||||
structure | 1 | float ball diameter:45mm. H1=40mm, H2=30mm | |||
2 | 76mm, H1=50mm, H2=40mm | ||||
3 | 125mm, H1=80mm, H2=65mm | ||||
Insallation | F | flange | |||
P | angle plate bracket | ||||
S | screw | ||||
A | adjustable screw is optional | ||||
Other function | P | pressure <0.6MPa | |||
E | explosion-proof | ||||
S | Digital display |